The method

From an audit
to a checklist.

ARCI measures how completely a study describes its audio chain. MARC-XR turns the same twelve domains into questions authors can use before publication.

How they were developed

  1. Define the audio chain

    The authors divided the information needed to reconstruct an XR auditory exposure into five areas: playback devices; rendering and spatialization; content and level control; environment, timing and hearing; and audio’s role and justification. These became the twelve ARCI domains.

  2. Pilot and refine the codebook

    A pilot on ten full-text XR studies combined audio-focused cases with general presence/UX studies. It clarified descriptions, examples, edge cases and the 0/1/2 scoring rules. The final codebook was fixed before the group comparison; all thirty papers were coded or recoded with that version.

  3. Audit thirty studies

    A 90-record screening corpus produced a 65-record retrieval queue. Sequential selection of eligible, open-access full texts continued until there were fifteen audio/multisensory and fifteen general presence/UX studies. This was a balanced feasibility sample, not a random sample of XR research.

  4. Code explicit evidence and check agreement

    GPT-5.6 Sol Pro assisted primary full-text coding. Credit required an explicit statement in the inspected article, tables or appendices; device capabilities and default settings were not inferred. One blinded domain expert independently recoded six papers, three randomly selected from each group. Across 72 paired domain ratings, exact agreement was 90.3% and linearly weighted Cohen’s κ was .887.

  5. Translate the findings into MARC-XR

    The audit found that studies often described what participants heard but gave less detail about delivery, rendering and control. MARC-XR v0.1 translates the twelve domains into a minimum reporting checklist, intended for expert review, community feedback and versioned refinement.

What the score means

Each domain receives 0, 1 or 2 points. All domains have equal weight: ARCI = (sum of the twelve scores ÷ 24) × 100. A higher score means more complete reporting. It does not certify sound quality, suitability of the setup, or reproducibility of the entire study.

Explicit absence can be informative: stating that no spatialization, calibration or timing assessment was used can receive full credit in the relevant domains. The hearing domain has a different anchor: “hearing was not assessed” receives 1. Use the domain-specific examples when scoring.

63.6Mean ARCI · Audio/multisensory
15 studies
27.2Mean ARCI · General presence/UX
15 studies

These are descriptive results for the selected sample, not prevalence estimates for the XR literature.

Scope and limits

  • ARCI is a preliminary reporting index. The paper does not claim a validated measurement scale or established human–human reliability.
  • The audit used a non-random, open-access feasibility sample. Separate supplements, repositories, websites and vendor documentation were not systematically inspected.
  • A score of 0 means the information was not specified in the inspected materials; it does not mean the practice did not occur.
  • ARCI v0.1 has no “not applicable” category and was not evaluated on genuinely audio-absent studies. Such cases need an applicability rule rather than an uncritical reading of the score.

MARC-XR supports transparent reporting of simple and advanced setups. Audio that is manipulated, spatialized, or essential to a task may need an extended technical description.

Source

ARCI and MARC-XR are based on our paper accepted for the Alt’ISMAR 2026 workshop at IEEE ISMAR 2026.

Magdalena Igras-Cybulska & Artur Cybulski (2026). The Elephant in the Ear: A Preliminary Audit of Audio-Chain Reporting in XR Presence Research.

View the Alt’ISMAR 2026 poster (PDF) ↗